6.15. Small-sized DELCO-REMY generator

Removal

PERFORMANCE ORDER
1. Remove the generator.
2. Remove a plastic casing from a back part of the generator.
3. Unscrew two bolts, the fixing brush holders and one bolt, the fixing condenser of suppression of hindrances.
4. Remove the condenser and take the brush holder, at the same time note an arrangement of the flat socket sideways.
5. Check smoothness of movement of brushes in guides and measure length of brushes.
6. Check a condition of contact rings of the generator and, if necessary, smooth out them a small emery paper.

Installation

PERFORMANCE ORDER
1. Installation is made in the sequence, the return to removal.