11.8. Cowl lock

Removal

PERFORMANCE ORDER
1. Open a cowl and record it in this situation.
2. A latch of safety of a cowl of a priklepan to a cowl. For removal of a latch of safety it is necessary to drill rivets, and at installation to use new rivets.
3. For removal of a shock plate of the lock of a cowl weaken a lock-nut, then unscrew a bolt of a shock plate and remove washers and a spring.
4. For removal of a spring of the lock of a cowl disconnect a cable of opening of a cowl from a spring. Take the second end of a spring from a groove in the forward panel of a body and take a spring through the top part of the panel.

Installation

PERFORMANCE ORDER
1. Installation is made in the sequence, the return to removal.
2. Close a cowl and check operation of the lock of a cowl and the mechanism of opening of the lock of a cowl.