5.3.10. Tube and unidirectional valve of system of reduction of toxicity
Prevention
At installation it is necessary to use new washers of an air branch pipe.
Removal
PERFORMANCE ORDER |
1. Remove an air hose однонаправ the lenny valve. |
2. Unscrew the bolts fixing an eye arm for raising of the engine and turn an arm to the left side. |
3. Unscrew three bolts and remove an arm of support of a pipe. |
4. Unscrew two bolts and remove a termoz the shchitny screen. |
5. Unscrew two bolts and remove an air branch pipe. |
6. If necessary, disconnect the unidirectional valve. |
7. Being careful, fix a pipe in a vice with soft sponges and unscrew the valve from a pipe. Clear the valve and check its state. |
|
Installation
PERFORMANCE ORDER |
1. Before installation apply a thin film of Opel No. 994714 sealant on a carving of the unidirectional valve. |
2. At installation of a pipe use new washers. Before a vvinchivaniye of bolts of fastening of a pipe apply Opel No. 90513210 paste on a carving of bolts. |
3. You make further installation in the sequence, the return to removal. |
|