4.14. Broad tank and sensor of level of cooling liquid
BROAD TANK
Removal
PERFORMANCE ORDER |
1. Fastening of a broad tank is carried out by one screw. If it is necessary to move a broad tank aside, unscrew the screw and, without disconnecting hoses from a broad tank, move it aside. |
2. Disconnect two top hoses from a broad tank and, having lifted up, tie up them in this situation to reduce loss of cooling liquid. |
3. Unscrew the screw, the fixing tank, and raise a tank up as far as possible. |
4. Install the corresponding container under a broad tank, then remove the lower hose and merge cooling liquid from a tank in a container. Tie up the lower hose of a broad tank as above for reduction of losses of cooling liquid is possible. |
|
Installation
PERFORMANCE ORDER |
1. Installation is made in the sequence, the return to removal. |
2. Check level and if necessary add cooling liquid. |
|
SENSOR OF LEVEL OF COOLING LIQUID
The sensor of level of cooling liquid is installed in a cover of a broad tank. If the sensor is faulty, it is necessary to replace it together with a cover of a broad tank.